详细介绍: NCU 573.5/573.4/573.3/573.2/572.5/572.4/572.3/572.2/571.5/561.5/571.4/571.3/571.2
NCU 572.2 6FC5357-0BB21-0AE0 现货特价
NCU 572.2 6FC5357-0BB21-0AE1 现货特价
NCU 572.2 6FC5357-0BB52-0AE0 现货特价
===================
上海启水自动化科技有限公司(西门子核心分销商)
联系人 :李 明 松( 销售经理 )24小时服务热线 :186 0165 7819
电话( Tel ): 021-60641328
工作( Q Q ) :1471187088 邮箱( Email )::1471187088@qq.com
地址( Add ):上海市松江区弘翔路58号195
公司优势产品系列=西门子S7-200CN | S7-300PLC | 触摸屏 | 变频器 | 伺服电机 | 数控系统 | 总线电缆| 开关电源
====================
We would like to inform you about a new component for the SINUMERIK 840D/DE control. The enhanced-performance NCU 573.2 Order No. ÄMLFBÜ 6FC5357-0BB33-0AE1 is released for general availability and is now available. It cannot be used as spare part for previous NCUs 573/573.2. The new NCU 573.2 has a performance which has been increased by to 40% regarding the computational performance (the Intel Pentium Pro processor 200 MHz has been replaced by the Pentium II 266 MHz with 256 kB cache) and the user memory has been increased from 1.5 to 2.5 MB. NCU Order No.ÄMLFBÜ Acquisitional text ----------------------------------------------------------- 573.2 6FC5357-0BB33-0AE1 SINUMERIK 840D/DE NCU 573.2 PENTIUM II WITHOUT SYSTEM SOFTWARE MEMORY: NC 2.5MB, PLC 64KB PREPARED FOR PROFIBUS-DP - The system software on PC card must be ordered separately specifying the software release! PRODOK Info No. 1998/060 is valid - NCU 573.2 can be upgraded, as before, using options: 6FC5252-0AA03-0AA0 PLC user memory expansion by 32 kB (this can be expanded up to 288 kB) 6FC5252-0AD00-0AA0 Peripheral interface via Profibus DP When ordered from LZE (new business) the previously supplied NCU 573.2, Order No.ÄMLFBÜ 6FC5357-0BB33-0AE0 will be substituted by the new NCU 573.2, Order No.ÄMLFBÜ 6FC5357-0BB33-0AE1 after the stock inventory has been reduced to zero (approx. middle of 6/99). The previous NCU 573.2 with Pentium Pro will remain available until further notice for spare parts supply. Compatibility: The new NCU 573.2 is compatible, as far as the hardware is concerned, to the previous NCU 573.2. The new NCU 573.2 however, requires the following software versions to offer full compatibility: SW-release Version Comments ------------------------------------------------------------------- 3.6 > V03.06.11 more detailed info will be provided 3.7 > V03.07.14 more detailed info will be provided 4.3 > V04.03.12/13/14 more detailed info will be provided completed on 28.07.99; Bader 4.4 V04.04.27 available from the end of 05/99 5.1 V05.01.2x available from the end of 05/99
|