当前位置:首页 >> 产品展示 >> 电工电气 >> 综合 >>961-087-000 961-107-000 电气转换器
961-087-000 961-107-000 电气转换器放大图片

产品价格:1   元(人民币)
上架日期:2012年9月25日
产地:
发货地:上海  (发货期:当天内发货)
供应数量:不限
最少起订:1个
浏览量:430
  暂无相关下载
其他资料下载:

         
上海冠佑电气自动化有限公司

点击这里给我发消息
  详细说明  
品牌:电气转换器产地:
价格:1人民币/个规格:

简要说明:

详细介绍:

 
上海冠佑电气自动化有限公司随时欢迎您的来电咨询,低价现货供应 。
电话:021-60483978  13916770581
传真:021-34689102  联系人:陈尉
商务QQ:1305857511  邮箱:2265736@163.com
网址:www.gyautomation.com
MARSH BELLORFAM(马士贝罗浮) 电气转换器 一级代理
Type 1000
 
Type 1000 I/P & E/P Transducers
  • Low Cost
  • Built-in Volume Booster
  • Small Size
  • Field Reversible
  • Low Air consumption
  • Mounts at Any Angle
  • Convenient External Span & Zero Adjusts
    (Except for Explosion Proof Models)
  • Light Weight
  • Wide Supply Pressure Range
  • Low Supply Pressure Sensitivity
Product Detail:
The Type 1000 Transducer is an electro-pneumatic device that reduces a supply pressure to a regulated output pressure directly proportional to an electrical input signal. The Type 1000 accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 BAR) above the maximum output up to 100 psig (6.9 BAR). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM/339 slpm). Model selections include general purpose, NEMA 4X Type, extended range, high relief, intrinsically safe, and explosion proof.
Part Numbers:
T-1000 General Purpose ordering information:
Input
Output*
Part Number
Impedance
(nominal)
psig
BAR
4-20mA
3-9
0.2-0.6
961-072-000
90Ω
9-15
0.6-1.0
961-073-000
90Ω
3-15
0.2-1.0
961-070-000
180Ω
3-27
0.2-1.9
961-074-000
220Ω
6-30
0.4-2.1
961-075-000
220Ω
1-17
0.07-1.2
961-116-000
250Ω
3-15
0.2-1.0
961-089-000
180Ω
10-50mA
3-15
0.2-1.0
961-076-000
70Ω
3-27
0.2-1.9
961-077-000
85Ω
6-30
0.4-2.1
961-078-000
85Ω
 
============
 
0-5V
3-15
0.2-1.0
961-079-000
615Ω
3-27
0.2-1.9
961-080-000
530Ω
6-30
0.4-2.1
961-081-000
530Ω
1-9V
3-15
0.2-1.0
961-085-000
985Ω
3-27
0.2-1.9
961-086-000
840Ω
6-30
0.4-2.1
961-087-000
840Ω
NOTE: For NEMA4X, add 004 suffix.
T-1000 extended range ordering information:
Input
Output*
Part Number
Impedance
(nominal)
psig
BAR
0-60mA
2-120
0.1-8.3
961-107-000
220Ω
4-20mA
3-120
0.2-8.3
961-111-000
260Ω
2-60
0.1-4.1
961-117-000
225Ω
0-10V
3-120
0.2-8.3
961-112-000
805Ω
0-5V
2-60
0.1-4.1
961-118-000
500Ω
T-1000 HIGH RELIEF ordering information:
Input
Output*
Part Number
Impedance
(nominal)
psig
BAR
4-20mA
3-9
0.2-0.6
961-130-000
90Ω
9-15
0.6-1.0
961-131-000
90Ω
3-15
0.2-1.0
961-132-000
180Ω
3-27
0.2-1.9
961-133-000
220Ω
6-30
0.4-2.1
961-134-000
220Ω
3-15
0.2-1.0
961-135-000
180Ω
1-17
0.07-1.2
961-136-000
250Ω
10-50mA
3-15
0.2-1.0
961-137-000
70Ω
3-27
0.2-1.9
961-138-000
85Ω
6-30
0.4-2.1
961-139-000
85Ω
* For output pressures less than 3 psi (0.2 BAR) or greater than 30 psi (21 BAR), the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay. Consult Applications Engineers for further information.
** NEMA 4 type enclosure option available on all input/output ranges. This option is separate from explosion proof, NEMA 4 units.
 
Type 1000 Explosion Proof
Input
Output*
Part Number
Impedance (nominal)
Agency Approvals
(see notes)
psig
BAR
4-20mA
3-15
0.2-1.0
961-098-000
180Ω
Explosion-Proof, Factory Mutual1
3-15
0.2-1.0
961-098-100
180Ω
CSA Explosion Proof
1-9v
3-15
20-100
961-142-000
985Ω
Explosion Proof Factory Mutual1
Type 1000 Intrinsically Safe
4-20mA
3-15
0.2-1.0
961-099-000
180Ω
Intrinsically Safe, Factory Mutual3,4
3-27
0.2-1.9
961-100-000
220Ω
Intrinsically Safe, Factory Mutual3,4
3-15
0.2-1.0
961-105-000
180Ω
Intrinsically Safe, CSA5
3-27
0.2-1.9
961-106-000
220Ω
Intrinsically Safe, CSA5
6-30
0.4-2.1
961-101-000
220Ω
Intrinsically Safe, Factory Mutual3,4
15-3
1.0-0.2
961-175-000
180Ω
Intrinsically Safe, Factory Mutual3,4
27-3
1.9-0.2
961-176-000
220Ω
Intrinsically Safe, Factory Mutual3,4
30-6
2.1-0.4
961-177-000
220Ω
Intrinsically Safe, Factory Mutual3,4
*For output pressures less than 3 psi or greater than 30 psi the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay.  Consult application engineers for further information.
Agency Approval Notes:
  1. The Type 1000 Explosion-Proof Transducer has been submitted, tested and approved by Factory Mutual Research for use in hazardous locations for Class I, Division 1, Group D, Class II, Division 1, Groups E, F & G and Class III requirements. It also has been approved to meet NEMA 4 Outdoor requirements.
  2. Canadian Standards Association certified for hazardous locations: Class I, Group D, Class II, Groups E, F and G, Class III, CSA Enc. 4.
  3. Factory Mutual Research Approved as intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, G when installed in accordance with interconnection diagram No. 541-000-012 and with the proper energy limiting barriers.
  4. Factory Mutual Research Approved as nonincendive for Class I, Division 2, Groups A, B, C, D, and suitable for Class II and III, Division 2, Group G. Barriers are not required for nonincendive rating.
  5. Canadian Standards Association certified as intrinsically safe when connected through certified diode safety barriers in accordance with Bellofram Installation Instruction 541-000-012.
Explosion proof, intrinsically safe, and non-incendive ratings are not affected by recalibrating for split range or reverse acting applications.
The Bellofram T-1000 Transducers were tested and found to comply with Electromagnetic compatibility Directive effective January 1, 1996. The relevant EMC specifications tested were the following: EN 50081-1 (1992) and EN 50082-1 (1992). A Technical Construction File, Serial #107 was written and Certificate of Conformity issued by a Competent Body.
Options:
Option
Part Number/Last 3 digits
Explosion Proof Mounting Kit
971-079-000
Explosion Proof Panel Mounting Kit
971-078-000
DIN Rail Kit
010-115-000
Hirschman Connector Kit (3-prong)
971-126-000
Filter Kit, Coalescing, 0.1 micron
010-140-000
Filter Element Kit
(for coalescing filter, package of 10)
010-141-000
Output Gauges–Option “8”
last 3 digits become - 008
Dielectric Strength Testing Option “12”
last 3 digits become - 012
NEMA 4X Type Enclosure Option: Option “4”
last 3 digits become - 004**
** NEMA 4 type enclosure option available on all input/output ranges. This option is separate from explosion proof, NEMA 4 units.

该公司其他信息
最新供求信息 企业产品推荐

暂无产品
  在线询盘/留言 请仔细填写准确及时的联系到你!  
您的姓名:
* 预计需求数量: *
联系手机:
*  移动电话或传真:
电子邮件:
* 所在单位:
咨询内容:
*
           您要求厂家给您提供:
  • 规格,型号
  • 价格及付款条件
  • 产品目录
  • 最低订货量
  • 运送资料
  • 提供样本
  • 库存情况
  • 包装材料

1关于我们 |  联系我们 |  广告合作 |  付款方式 | 使用帮助 | 本站诚聘 | 代理加盟
电话:0571-87774297(杭州) 传真:0571-87774298(杭州)