PW100系列 / PW100 Series
《產品介紹 note》:
產品編碼
Code No.
|
倍比
Ratio
|
輸出壓力
Outlet Pressure(Ph*)
|
吐出量(往返一次)
Fluid volume for cycle
(L/cycle)
|
耗氣量(往返一次)
Consumption for cycle
(L/cycle)
|
PW100004
|
4:1
|
3Pd+Ps
|
2.24
|
(1.586xPd+1.639)/1.033
|
PW100006
|
6:1
|
5Pd+Ps
|
1.44
|
PW100011
|
11:1
|
10Pd+Ps
|
0.81
|
PW100016
|
16:1
|
15Pd+Ps
|
0.56
|
PW100025
|
25:1
|
24Pd+Ps
|
0.36
|
PW100038
|
38:1
|
37Pd+Ps
|
0.23
|
* PH= Outlet Pressure / ** PD= Driven Pressure / *** PS = Supply Pressure / Pressure Ratio=PH/PD / signal pressure≥ Pd pressure』
附註:設定驅動壓(PD) = 6 kg/cm2, 被壓縮壓(PS) = 6 kg/cm2壓力時,則『每分鐘PH輸出量』及『驅動壓(PD)往返一次耗氣量』所得到的數值如表格內所載明.
Note :If Driven Pressure (PD) is 6 kg/cm2, Supply Pressure (PS) is 6 kg/cm2 pressure, the 『Per minute PH of output』and 『Driven pressure consumption by cycle』the resulting values in the form described.
舉例:當氣體增壓泵浦規格為PW100025,在PD=6 kg/cm2且 PS=6 kg/cm2的壓力時,則『每分鐘PH輸出量』所得之計算數值為:20 l/min;另外『驅動壓(PD)往返一次耗氣量』所得之計算數值為10.8L
For example: When High Pressure Gas Booster specifications for PW100025, in the PD is 6 kg/cm2 and PS is 6 kg/cm2 pressure, the 『Per minute PH of output』of calculated values are: 20 l/min; Additionally 『Driven pressure consumption by cycle』of calculated values to 10.8L.
規格及外觀本公司擁有異動的權益,不另行通知,如蒙採購請與敞公司業務部門聯絡,以利新版本更換.
We reserve the rights of changing Specifications and Appearances of the products without previous notice. Please contact to our Sales Department for latest product information.
產品編號Code No. :??請選擇 choose?PW100004?PW100006?PW100011?PW100016?PW100025?PW100038??